Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorMert, Ahmet
dc.contributor.authorSezdi, Mana
dc.contributor.authorAkan, Aydın
dc.date.accessioned2021-06-05T19:57:06Z
dc.date.available2021-06-05T19:57:06Z
dc.date.issued2015
dc.identifier.issn1300-0632
dc.identifier.issn1303-6203
dc.identifier.urihttps://doi.org/10.3906/elk-1306-224
dc.identifier.urihttps://hdl.handle.net/20.500.12960/436
dc.description0000-0003-4236-3646en_US
dc.description0000-0001-8894-5794en_US
dc.descriptionWOS:000356355100019en_US
dc.description.abstractThe Doppler effect is the preferred technique in fetal heart rate (FHR) monitoring devices. The main objective of the recent studies on the Doppler FHR has been to improve the accuracy. On the other hand, a reliable fetal heart simulator becomes essential for testing Doppler FHR monitoring devices. The motivation of this study is to design a reliable system that will be used to test Doppler FHR monitors. This device generates a similar Doppler frequency shift of fetal cardiac activity including the heart's wall and valve motions. The components of this system are basically a signal generator using a microcontroller and a modified relay. The relay is the most important and studied component that affects the Doppler frequency shift. Thus, the relay's contact distance and length as well as its closing and opening velocities have been modified to produce an appropriate Doppler shift to fetal cardiac motion. This device has been tested and its reliability has been proved.en_US
dc.description.sponsorshipResearch Fund of Istanbul UniversityIstanbul University [UDP-35119, UDP-25231]en_US
dc.description.sponsorshipThis work was partially supported by the Research Fund of Istanbul University, Project Numbers UDP-35119 and UDP-25231.en_US
dc.language.isoengen_US
dc.publisherTubitak Scientific & Technical Research Council Turkeyen_US
dc.relation.ispartofTurkish Journal on Electrical Engineering and Computer Sciencesen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDoppler Effecten_US
dc.subjectFetal Heart Simulationen_US
dc.subjectFetal Heart Rateen_US
dc.subjectFetal Monitoringen_US
dc.subjectUltrasounden_US
dc.subjectQuality Controlen_US
dc.titleA test and simulation device for Doppler-based fetal heart rate monitoringen_US
dc.typearticleen_US
dc.departmentMühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.department-temp[Mert, Ahmet] Piri Reis Univ, Dept Elect & Elect Engn, Istanbul, Turkey; [Sezdi, Mana] Istanbul Univ, Dept Biomed Device Technol, Istanbul, Turkey; [Akan, Aydin] Istanbul Univ, Dept Elect & Elect Engn, Istanbul, Turkeyen_US
dc.contributor.institutionauthorMert, Ahmet
dc.identifier.doi10.3906/elk-1306-224
dc.identifier.volume23en_US
dc.identifier.issue4en_US
dc.identifier.startpage1187en_US
dc.identifier.endpage1194en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster